Engineering reference · reviewed 8 October 2026

Allen-Bradley MicroLogix: which models are discontinued?

MicroLogix lifecycle status varies by model. Several families have been discontinued, while the 1400 has been listed as Active Mature. Do not assume the whole MicroLogix range has a single end-of-sale date.

Important lifecycle distinction

MicroLogix lifecycle status varies by model. Several families have been discontinued, while the 1400 has been listed as Active Mature. Do not assume the whole MicroLogix range has a single end-of-sale date.

Lifecycle milestones by product family

FamilyCurrent reference statusLast order / productionSupport / repairs
Allen-Bradley MicroLogix 1000 (1761)Discontinuednot publishedNot published
Allen-Bradley MicroLogix 1100 (1763)Discontinuednot publishedNot published
Allen-Bradley MicroLogix 1200 (1762)Discontinuednot publishedNot published
Allen-Bradley MicroLogix 1400 (1766)Active Maturenot publishednot published
Allen-Bradley MicroLogix 1500 (1764)Discontinuednot publishedNot published

Lifecycle status may vary by exact catalogue number, hardware series and market. Confirm the precise reference with the manufacturer before relying on any deadline.

Successors and migration considerations

  • Allen-Bradley MicroLogix 1000 (1761): Micro800 (Rockwell MicroLogix to Micro800 modernisation guide)
  • Allen-Bradley MicroLogix 1100 (1763): Micro800
  • Allen-Bradley MicroLogix 1200 (1762): Micro800
  • Allen-Bradley MicroLogix 1400 (1766): Micro800 (Rockwell lists a replacement)
  • Allen-Bradley MicroLogix 1500 (1764): Micro800 or CompactLogix

Migration is an engineering assessment, not an automatic drop-in substitution. Check program conversion, field wiring, communications, safety and commissioning requirements.

Find available spares

Inventory changes as items are sold and new consignments arrive, so we do not publish fixed quantities or condition claims on these reference guides.

Questions engineers ask

Does discontinued mean an installed controller must be replaced immediately?

No. It means the product's commercial lifecycle has changed, not that every installed unit has stopped functioning. Review spares availability, reliability, risk and your maintenance strategy.

Can Automation Outlet help source a legacy spare?

Yes. Send us the exact manufacturer part number, revision or series, quantity and required condition. Availability and testing status must be confirmed before an order.

Can a listed successor be swapped directly into my system?

Not necessarily. Replacement can require changes to software, wiring, communications, safety assessments and commissioning. Confirm compatibility with manufacturer documentation.

Manufacturer and supporting references

  1. Allen-Bradley MicroLogix 1000 (1761): Source document ↗ · Additional reference ↗
  2. Allen-Bradley MicroLogix 1100 (1763): Source document ↗ · Additional reference ↗
  3. Allen-Bradley MicroLogix 1200 (1762): Source document ↗
  4. Allen-Bradley MicroLogix 1400 (1766): Source document ↗
  5. Allen-Bradley MicroLogix 1500 (1764): Source document ↗

Editorial review: 20 October 2026 · Prepared by Automation Outlet, an independent UK engineering business. Technical information is not a guarantee of stock, support entitlement or interchangeability.