Engineering reference · reviewed 20 October 2026

Modicon Premium and Quantum: end-of-service dates

Schneider Electric lifecycle dates differ by exact TSX or 140 catalogue number. Use the manufacturer references below to verify whether a CPU, rack or module can still be ordered or supported.

Important lifecycle distinction

Schneider Electric lifecycle dates differ by exact TSX or 140 catalogue number. Use the manufacturer references below to verify whether a CPU, rack or module can still be ordered or supported.

Lifecycle milestones by product family

FamilyCurrent reference statusLast order / productionSupport / repairs
Modicon Premium (TSX)Discontinued: service onlyEnd of active sale 31 Dec 2018 (per Schneider notice reported by partners); se.com shows e.g. TSXP573634M and TSXAEY414 discontinued 2 Dec 2020End of standard service 31 Dec 2026 (se.com product pages)
Modicon Quantum (140)End of commercialisation: dates per referenceSelected 140 I/O ended 31 Dec 2021; remaining references removed from active sale 31 Dec 2022, obsolescence 15 Jan to 31 Dec 2023 (Schneider notice). Some 140 I/O still orderable to 31 Dec 2030 per se.comPer reference: e.g. 140CPU43412UC ended 8 Oct 2025; others 31 Dec 2026 to 31 Dec 2030

Lifecycle status may vary by exact catalogue number, hardware series and market. Confirm the precise reference with the manufacturer before relying on any deadline.

Successors and migration considerations

  • Modicon Premium (TSX): Modicon M580 / Modicon X80 I/O (se.com names e.g. BMXART0414 for TSXAEY414)
  • Modicon Quantum (140): Modicon M580 (Quantum Ethernet I/O / X80)

Migration is an engineering assessment, not an automatic drop-in substitution. Check program conversion, field wiring, communications, safety and commissioning requirements.

Find available spares

Inventory changes as items are sold and new consignments arrive, so we do not publish fixed quantities or condition claims on these reference guides.

Questions engineers ask

Does discontinued mean an installed controller must be replaced immediately?

No. It means the product's commercial lifecycle has changed, not that every installed unit has stopped functioning. Review spares availability, reliability, risk and your maintenance strategy.

Can Automation Outlet help source a legacy spare?

Yes. Send us the exact manufacturer part number, revision or series, quantity and required condition. Availability and testing status must be confirmed before an order.

Can a listed successor be swapped directly into my system?

Not necessarily. Replacement can require changes to software, wiring, communications, safety assessments and commissioning. Confirm compatibility with manufacturer documentation.

Manufacturer and supporting references

  1. Modicon Premium (TSX): Source document ↗ · Additional reference ↗

    Dates vary by reference.

  2. Modicon Quantum (140): Source document ↗ · Additional reference ↗

    Always check the exact 140 reference; C (coated) versions have different dates.

Editorial review: 20 October 2026 · Prepared by Automation Outlet, an independent UK engineering business. Technical information is not a guarantee of stock, support entitlement or interchangeability.